配电箱安装14大禁忌,贵州配电柜提醒大家一定要仔细观看!

配电箱安装14大禁忌,贵州配电柜提醒大家一定要仔细观看!

发布日期:2017-05-15 00:00 来源://www.9notesstudycircle.com 点击:

配电箱安装14大禁忌,贵州配电柜提醒大(da)家一定要仔细(xi)观看!


禁(jin)忌1:照(zhao)明配(pei)电箱(板)进场未做(zuo)检查。 


后(hou)果:照明(ming)配电箱(板(ban))进(jin)场未做检(jian)查,往往在安(an)装后(hou)才发(fa)现:贵州配电柜其二层(ceng)板(ban)没(mei)有(you)(you)专用(yong)接地螺(luo)(luo)栓,保护地线(xian)(xian)截面小,装有(you)(you)电器的(de)可开启门(men)没(mei)有(you)(you)用(yong)裸(luo)铜(tong)软线(xian)(xian)与金(jin)属(shu)构(gou)架(jia)可靠(kao)连接,导线(xian)(xian)与器具连接不(bu)(bu)牢固(gu)、有(you)(you)反(fan)圈现象,螺(luo)(luo)丝(si)母不(bu)(bu)用(yong)镀(du)锌件,导线(xian)(xian)线(xian)(xian)径不(bu)(bu)符合要求(qiu),没(mei)有(you)(you)按(an)色(se)标标识,没(mei)有(you)(you)卡片柜和电气线(xian)(xian)路图,器具布局(ju)、间(jian)隔不(bu)(bu)合理,没(mei)有(you)(you)设(she)置N和PE端子(zi)排(pai)等。再修改延误工期也影响质量。

措施:首(shou)先在加工订货(huo)时(shi)就应向(xiang)厂家(jia)提(ti)出符合设计和(he)规(gui)范(fan)标准(zhun)(zhun)的技术(shu)要求,请厂家(jia)做出样品,经验收合格(ge)后,再生产(chan);并在产(chan)品进场时(shi)严格(ge)按设计和(he)规(gui)范(fan)标准(zhun)(zhun)要求进行(xing)检查(cha)验收,确认合格(ge)后再进行(xing)安装。  


禁忌2:照明(ming)配电箱(板)使用未经(jing)阻燃处理(li)的木质材料。

后果:照明配电箱(xiang)(xiang)(板)若在潮湿多尘场所使用木制(zhi)的容易(yi)(yi)霉烂(lan)和漏(lou)电;另外,木制(zhi)的箱(xiang)(xiang)(板)不经过阻燃处(chu)理(li),容易(yi)(yi)引发火灾,是不安(an)全(quan)的隐(yin)患。 


措施:为(wei)保证安全使用(yong),要求照明配电箱(板(ban)(ban))不应(ying)采用(yong)可燃材料制(zhi)(zhi)作。即使在于燥无(wu)尘的场所,采用(yong)的木制(zhi)(zhi)配电箱(板(ban)(ban))也应(ying)经阻(zu)燃处理后才能用(yong)。


禁忌3:照明配电箱(板)安装不(bu)牢固,标高不(bu)符合要求,暗(an)装时,其面板四周边(bian)缘不(bu)紧贴墙面。

后(hou)果:照明配电箱(板)安装的(de)标高(gao)不(bu)符合规定,安装不(bu)牢固,箱体不(bu)垂直(zhi),暗装时,其面板四周边(bian)缘不(bu)紧(jin)贴墙面,影响使用功能(neng),观感不(bu)好。

措施(shi):标高(gao)应(ying)(ying)符合设计(ji)要求,设计(ji)没规定(ding)时,贵州配(pei)电(dian)柜照明(ming)(ming)配(pei)电(dian)箱(xiang)底边距地面高(gao)度宜(yi)为(wei)(wei)1.5m。照明(ming)(ming)配(pei)电(dian)板(ban)底边距地高(gao)度宜(yi)为(wei)(wei)1.8m。 照明(ming)(ming)配(pei)电(dian)箱(xiang)(板(ban))安装(zhuang)应(ying)(ying)牢固,安装(zhuang)垂直度允许偏差不应(ying)(ying)大于3mm,暗装(zhuang)时,配(pei)电(dian)箱(xiang)四周(zhou)应(ying)(ying)无(wu)空隙,面板(ban)四周(zhou)边缘应(ying)(ying)紧(jin)贴墙面,箱(xiang)体(ti)与(yu)建筑物、构筑物接触部位涂防腐漆。 


禁忌4:照明配电箱(xiang)(板)内(nei)线路(lu)交叉凌乱,未绑扎成束(shu)。 

后果:照明配电箱(xiang)(板(ban)(ban))内(nei)(nei)线(xian)路凌乱,箱(xiang)内(nei)(nei)二层板(ban)(ban)紧(jin)压管(guan)口,影响导(dao)线(xian)进入箱(xiang)体,若(ruo)勉强(qiang)挤(ji)进,时间长了导(dao)线(xian)绝缘损伤,容(rong)易造(zao)成短路。并使检(jian)修不便,影响观感。


措施:照明(ming)配电箱(xiang)使用金(jin)(jin)属箱(xiang)时,要(yao)(yao)做(zuo)防锈防腐处理。箱(xiang)内(nei)出(chu)线(xian)孔(kong)(kong)不(bu)可用电气(qi)焊开(kai)孔(kong)(kong),要(yao)(yao)一(yi)管(guan)一(yi)孔(kong)(kong),金(jin)(jin)属箱(xiang)孔(kong)(kong)要(yao)(yao)在穿线(xian)之前(qian)将防护套装好(hao)。 线(xian)路要(yao)(yao)排(pai)列整齐,管(guan)入箱(xiang)体的(de)位(wei)置要(yao)(yao)合理布(bu)局,不(bu)要(yao)(yao)让(rang)二层板紧压(ya)管(guan)上,箱(xiang)内(nei)导线(xian)应(ying)顺直盘(pan)在箱(xiang)体四周,并绑扎成束整齐。 


禁(jin)忌5:照明配(pei)电(dian)箱(xiang)(板)内不设置N和PE汇流排(pai)。 

后果:照明(ming)配(pei)电箱(板)内不设置N和PE汇流排,无法保证线(xian)路安全运行。


措施:照(zhao)明配电(dian)箱(板)内,应分别设置(zhi)零(ling)(ling)线(xian)(N线(xian))和保护地(di)线(xian)(PE线(xian))汇(hui)流(liu)排(pai),零(ling)(ling)线(xian)和保护地(di)线(xian)应在(zai)汇(hui)流(liu)排(pai)上连(lian)接,不得绞接,并应有(you)编号。 


禁忌6:照(zhao)明配电箱(板(ban))装设的螺旋(xuan)熔断器其接线不(bu)正。

后(hou)果:照明配(pei)电(dian)(dian)箱(板)装设的螺旋(xuan)熔断器接线不正确将(jiang)电(dian)(dian)源线接到(dao)螺纹的端子上(shang),影响更(geng)换熔芯(xin),而且操作不当,还容易引发(fa)触电(dian)(dian)事(shi)故。 


措施:为保(bao)证安(an)全,照明配电(dian)箱(板)内(nei)装设的(de)螺旋熔(rong)断(duan)器(qi),其电(dian)源线应接(jie)在中间(jian)触点的(de)端子上,负荷线应接(jie)在螺纹(wen)的(de)端子上。 


禁忌7:照明(ming)配电箱(xiang)(板)保(bao)护(hu)线(xian)做得不到位,线(xian)径不符合(he)。

后果(guo):照明配电箱(板)的(de)(de)保(bao)护线(xian)不(bu)(bu)从端(duan)子排列出,而(er)是利用箱体构架串接,线(xian)径(jing)不(bu)(bu)按要求设,配电箱门(men)有(you)超安(an)(an)全电压(ya)的(de)(de)器件不(bu)(bu)设置(zhi)保(bao)护地(di)线(xian),容(rong)易(yi)引发(fa)安(an)(an)全事(shi)故。 


措施:按(an)(an)照规范要(yao)求,贵州配(pei)电(dian)(dian)(dian)(dian)柜照明配(pei)电(dian)(dian)(dian)(dian)箱(板)内(nei),应(ying)(ying)设保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)汇(hui)流排,保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)应(ying)(ying)在汇(hui)流排上连(lian)接(jie)。 保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)的(de)截(jie)面积不应(ying)(ying)小于从电(dian)(dian)(dian)(dian)源到所属电(dian)(dian)(dian)(dian)器(qi)最大(da)引线(xian)(xian)(xian)的(de)截(jie)面积;而且(qie)还应(ying)(ying)按(an)(an)有(you)关规定(ding)选择。配(pei)电(dian)(dian)(dian)(dian)箱(板)上接(jie)地(di)(di)(di)应(ying)(ying)牢(lao)固良好,并必须有(you)防松装(zhuang)(zhuang)置(zhi)。装(zhuang)(zhuang)有(you)超过(guo)50V电(dian)(dian)(dian)(dian)器(qi)设备的(de)可(ke)开启的(de)门(men),活(huo)动面板应(ying)(ying)以裸铜软线(xian)(xian)(xian)与接(jie)地(di)(di)(di)良好的(de)金属构架可(ke)靠连(lian)接(jie)。裸铜软线(xian)(xian)(xian)的(de)截(jie)面积也应(ying)(ying)按(an)(an)规定(ding)选择。而壁厚小于2.5mm的(de)金属箱、盒本(ben)体(ti)不应(ying)(ying)作(zuo)为管路的(de)跨接(jie)地(di)(di)(di)线(xian)(xian)(xian)和用(yong)电(dian)(dian)(dian)(dian)器(qi)具的(de)保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)压接(jie)点。保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)的(de)截(jie)面积按(an)(an)表(biao)保(bao)(bao)(bao)(bao)护(hu)地(di)(di)(di)线(xian)(xian)(xian)的(de)截(jie)面积(mm2)装(zhuang)(zhuang)置(zhi)的(de)相(xiang)导(dao)(dao)线(xian)(xian)(xian)的(de)截(jie)面积S相(xiang)应(ying)(ying)的(de)保(bao)(bao)(bao)(bao)护(hu)导(dao)(dao)线(xian)(xian)(xian)的(de)截(jie)面积SP    

S≦16      ;             SP=S      

16≦S≦35             SP=16        

S>35                 SP =S/2 


禁忌8:照明配(pei)电箱(xiang)(板(ban))内闸具未标明回路名称。

后果:照明配(pei)电箱(xiang)(板)内的闸具不(bu)标回路(lu)名称(cheng),给(ji)使用和维修带来不(bu)便,若是误合不(bu)该(gai)合的闸,容易引发安全事故。


措施:一般按规范标准(zhun)要求,照(zhao)明配电箱(xiang)(板(ban)(ban))门(men)内(nei)应(ying)贴有(you)线路系统(tong)图,而在闸具上应(ying)标明回路名称(cheng),尤(you)其是(shi)照(zhao)明配电箱(xiang) (板(ban)(ban))内(nei)若有(you)交流(liu)、直流(liu)或不同等(deng)级的(de)电源,更应(ying)具有(you)明显的(de)标志。给(ji)使用人员(yuan)和维修人员(yuan)的(de)工作带来方便和安全。 


禁忌(ji)9:照明(ming)配电(dian)箱,(板)内的电(dian)具、仪表安(an)装不牢固、不平整,间距不符合(he)要求。

后果:照明配电箱(板)内的电具、仪表(biao)安(an)装不牢固、平整、间距不够等,影响使用安(an)全。 

措施:照明(ming)配电箱(板)上电具、仪表应(ying)安装牢固(gu)、平整(zheng)、整(zheng)洁(jie),间距应(ying)均匀、铜端子无松动,启闭灵活,零部(bu)件齐全。


禁忌10:照明(ming)配电箱(板)内的导线(xian)(xian)不按色标穿线(xian)(xian)。

后果:若不按色标穿线,在(zai)使用单相电路时(shi),由于(yu)不容易辨认(ren)三相电源,就很难将(jiang)负载均衡,造成(cheng)严重(zhong)的(de)三相不平衡,而在(zai)使用三相设备时(shi),由于(yu)没(mei)有(you)色标,接线时(shi)容易将(jiang)相序混(hun)接,在(zai)有(you)的(de)设备运行需(xu)要(yao)固(gu)定(ding)转(zhuan)向(xiang)(xiang)时(shi),又不好把握(wo)其(qi)旋转(zhuan)的(de)方向(xiang)(xiang)。


措施(shi):为了保证安全和施(shi)工方便(bian)照明配(pei)(pei)电(dian)箱(xiang)(板(ban))内的导线按(an)规定(ding)穿入管(guan)(guan)内的干(gan)线可不分色(se),但线管(guan)(guan)管(guan)(guan)口至配(pei)(pei)电(dian)箱(xiang)(板(ban))总开关的一段干(gan)线回路及各用电(dian)支路应按(an)色(se)标要求分色(se)。这(zhei)样在使用单相(xiang)回路时(shi),就能(neng)较好(hao)地均衡(heng)其负(fu)载(zai),而在使用三相(xiang)电(dian)源时(shi),按(an)相(xiang)序(xu)接线,从而保证设备的正常运行。


禁忌11:照明配(pei)电箱(xiang)(板(ban))内(nei)可拆卸的(de)金属板(ban),未与保护(hu)地线(xian)系统连接。 

后果:照明(ming)配(pei)(pei)电(dian)箱内的(de)可拆卸的(de)金属(shu)板上装(zhuang)配(pei)(pei)有各种的(de)电(dian)器配(pei)(pei)件,不接保(bao)护地线,容易引发(fa)触电(dian)事故。


措施:照明配电箱内的(de)可拆卸的(de)金属板应(ying)有可靠的(de)接地(di)(di)(di)保(bao)护(hu),因此要求该(gai)金属板上应(ying)设置有不(bu)可拆卸的(de)专用接地(di)(di)(di)螺丝(si),保(bao)护(hu)地(di)(di)(di)线应(ying)与其有效连接。保(bao)护(hu)地(di)(di)(di)线的(de)线径应(ying)按规范(fan)标准要求配,以保(bao)证安全(quan)使用。 


禁忌12:照明配电(dian)箱设在竖井内的位置(zhi)不当。

后果:照明配电箱设在(zai)竖井(jing)内,由(you)于竖井(jing)内一(yi)般都有(you)强、弱电,而(er)且空间很狭(xia)小,不便于操作,稍有(you)不慎,容易(yi)引发(fa)安(an)全事(shi)故。 


措施(shi):在(zai)接到(dao)图纸后,应(ying)(ying)认真审图,若发(fa)现竖(shu)井(jing)内各电(dian)气管道、箱体的布(bu)局不(bu)能满足(zu)规范标准(zhun)的要求,应(ying)(ying)在(zai)设计交(jiao)底时提出(chu)。 一般要求在(zai)电(dian)气竖(shu)井(jing)内的照明配(pei)电(dian)箱、端(duan)子箱前宜(yi)留(liu)有不(bu)小(xiao)于o.8m的操作维护距离。并为防止(zhi)强(qiang)电(dian)对(dui)弱(ruo)(ruo)电(dian)的干扰,将强(qiang)电(dian)和弱(ruo)(ruo)电(dian)分别(bie)布(bu)置在(zai)竖(shu)井(jing)的两(liang)侧或采(cai)取隔离措施(shi)。 


禁忌13:落(luo)地式配电箱(xiang)内的电线管路敷设(she)过低。

后果:落地式(shi)配电箱内(nei)敷设的(de)电线(xian)(xian)管(guan)路管(guan)口过低,容易使(shi)积水及杂(za)物进入管(guan)内(nei),降(jiang)低导线(xian)(xian)的(de)绝缘强(qiang)度(du)。 


措施:落地式配电(dian)箱内的电(dian)线保护管(guan)(guan),贵州配电(dian)柜管(guan)(guan)口宜高出配电(dian)箱基础面(mian)50~80mm。管(guan)(guan)路应(ying)排列(lie)整齐,管(guan)(guan)口应(ying)呈喇叭形。 


禁忌14:配线和(he)电气装置照明工程中(zhong)所有的金属附件不是镀锌件也不作防腐处理。 

后果:金属附件不是镀锌(xin)件或不作(zuo)防腐处理(li),极易腐蚀,使用寿命(ming)缩短。 


措施(shi):为保证工(gong)程(cheng)质量和延长使(shi)(shi)用(yong)寿命,要求在(zai)配线和电气(qi)装置照明工(gong)程(cheng)中(zhong)所使(shi)(shi)用(yong)的金(jin)属附件(jian)如管卡、支架(jia)、吊(diao)钩(gou)、拉环和盒(箱)螺栓、螺母等黑色金(jin)属附件(jian),均应(ying)镀锌或(huo)涂(tu)防腐漆。